Add to Cart
EWD-H-XJ3 Elevator parts load weighting device ,load cell,elevator load sensor
INTRODTION MANUAL
1 |
Scope of application |
Applicable to all elevators with movable platform car. range of auto-detention (2.0mm ≤car bottom displacement≤10.00mm ); range of manual set displacement: 2.5~9.9mm ( relate to parameter PD) |
|||
2 |
sensitivity |
Rated load /200 (5.0kg when rated load is 1 ton) |
|||
3 |
System error |
≤1.5% ( 5~40℃ ) |
Working temperature range≤3.0% |
||
4 |
nonlinearity |
≤1.0% |
|||
5 |
Output form |
Solid state relay |
Programmable universal signal |
① 3 channel programmable output mode are following: no- load, light- load, semi-load, heavy load, rated load and overload (user can freely set up the range of change. ② Each channel can be programmed as dynamic close or dynamic break contact. ③ Contact capacity: DC/AC 32V/15mA |
|
6 |
Storage environment |
-25~75℃ |
|||
7 |
Working environment |
Temperature:-20~55℃ |
|||
8 |
Relative humidity |
20%~99%RH |
|||
9 |
Reaction time |
≤0.25s |
|||
10 |
Power supply |
AC/DC24(10%)V/150mA |
|||
11 |
Installation position |
movable platform car of elevator |
|||
12 |
Machine dimension |
45X45X90㎜3 |
Product appearance, internal structure and interface specifications:
If you need details, please send us for this product "user manual".