Add to Cart
INTRODTION MANUAL
● This system is applicable to all elevators with movable car platform in need of overload signals. This device is of extremely high performance-price ratio. This appliance is to overcome the inherent disadvantage of the mechanical overload switch and to replace it.
⒈ |
Application Range |
Applicable to all elevators with movable car platform in need of overload signal with a inspection clearance of 8~15㎜. |
2 |
Sensitivity |
Overload turning point≤Rated load adjusting point±0.05㎜ Rated load→overload retention gap≈0.50mm |
3 |
System Error |
≤1.5% (5~40℃) |
4 |
Output Mode |
1 pair of relay dynamic CLOSE or dynamic OPEN contacts respectively with the capacity of DC/AC 48V/500mA. |
5 |
Operation Ambient Temperature |
-25~55℃ |
6 |
Power Supply |
AC/DC 24V(±10%)/15mA. The operating current of the whole machine≤100 mA. |
7 |
Install Position |
Movable elevator car platform |
8 |
Overall Size |
Column of Φ24×83 mm |
This system weighs the elevator car load based on the principle of the elastic deformation of movable elevator car platform caused by loading with the HALL sensor measuring the change of displacement, fulfilling the aim of load weighing.
Adjustment
Do use the Dyn. Open or Dyn. Close at the same time with full load
or overload when system wiring, avoiding cross using.
Wire |
Function |
Explanation |
||
Red, black(gray) |
System Operating Power |
Operating Power AC/DC24V(±10%)/100mA |
||
White (brown) |
blue |
Full load relay |
Dyn. close contact |
contact capacity:DC/AC 48V/500mA
|
yellow |
Dyn. open contact |
|||
green |
blue |
Overload realy |
Dyn. close contact |
|
yellow |
Dyn. open contact |
Attention : Output wire of this device must not be connected with external power supply to avoid everlasting damage.
Accessory: Inductive magnet [20×20×3mm3] 1 piece Fastening Nut Φ4X20 : 2 sets
If there is any abnormality during adjustment or operation, contact our company directly.
1. The inductive magnet is specially made of rare earth magnet with strong magnetism for this product. Take special care in the course of installation. Don’t let it close to the high temperature above 100℃ to avoid demagnetization and our company will not be responsible for the personal hurt and equipment damage arising from this.
2. It is suitable for massive purchase.
XI'AN Excellent Electromechanical Co. Ltd