Xi'an Excellent Electromechnical Co.,Ltd

E-mail:sales02@xaest.com whatsapp:008615710486683

Manufacturer from China
Active Member
9 Years
Home / Products / Car Platform installation /

ECW-P1 Elevator parts load weighting device for car platform installation

Contact Now
Xi'an Excellent Electromechnical Co.,Ltd
Province/State:Shaanxi
Country/Region:china
Contact Person:MissCherry
Contact Now

ECW-P1 Elevator parts load weighting device for car platform installation

Ask Latest Price
Video Channel
Place of Origin :China
Brand Name :EST
Certification :ISO9001
Model Number :ECW-P1
MOQ :50SETS
Price :USD 0-20/SET
Packaging Details :1 PC/Small box,50 PCS/ Carton
Delivery Time :7-10 working days by DHL,EMS,Container ets
Payment Terms :TT, Paypal, Western Union
Supply Ability :10000 piece /Month
Type :Elevator parts
Model :ECW-P1
output mathod :overload signal 1 open and one close
logic :sharing com with the power ,independent output
Power supply :AC/DC 24V
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

ECW-P1 Elevator parts load weighting device/elevator load cell from China

Type ECW-P1 Elevator Load Weighing Device

INTRODTION MANUAL

  • This system is applicable to all elevators with moveable car platform in need of overload signals and escalators in need of energy saving. This device is of extremely high ratio of property to price. Its appearance is to overcome the inherent disadvantage of the mechanical overload switch and to replace it.
  • Main Property:
  • 1.Working in a contactless and inductive way. No mechanical movement itself. Being directly installed in the original place of overload switch. No necessity of changing the mechanism of elevator car.
  • 2.Adopting strong inductive magnet, improving the anti-interference of the system to the utmost.
  • 3.The electrical property is in compliance with the standard of the International Electrotechnical Commission (IEC).

4.More accurately positioning, small overall size, easy installation and adjustment, simple structure and low price.

Technical date:

Application Range

Applicable to all elevators with moveable car platform in need of overload signal with a inspection clearance of 8~15㎜.

2

Sensitivity

Overload turning point≤Rated load adjusting point±0.05㎜

3

System Error

≤1.5% (5~40℃)

4

Output Mode

1 pair of relay dynamic CLOSE and dynamic OPEN contacts respectively with the capacity of DC/AC 48V/500mA.

5

Operation Ambient Temperature

-25~55℃

6

Power Supply

AC/DC 24V(±10%)/15mA. The operating current of the whole machine≤100 mA.

7

Install Position

Moveable elevator car platform

8

Overall Size

Column of Φ24×70 mm

  • Working Principle:

This system weighs the elevator car load based on the principle of the elastic deformation of moveable elevator car platform caused by loading with the HALL sensor measuring the change of displacement, fulfilling the aim of load weighing.

Installation:

  • Adjustment
  • Please refer to the above figure to install this device with the connecting support (made by the customer himself) closing the middle part of the car platform as near as possible.
  • Let the magnet adhesive on the car platform with the marking-face right facing the induction point of the device.
  • Install and adjust this device so that the magnet on the car platform aiming at the center point of its upper face. Meanwhile, assure the end face of this device in parallel with that of the magnet.
  • When elevator is of rated loaded, adjust this device up and down to make the indicator just turn from dark to bright (or oscillating), at this time, fasten this device and the adjustment is finished.
  • The principle of system wiring:
  • Comparison of the functions with other load weighing devices
  • ECW-P1

    Mechanical overloading switch

    Working Principle

    By the use of Hall sensor, the working way of contactless induction is realized.

    Advantages:①The system doesn’t bear the elevator load directly, extending its life.②Overloading signal is of point turning to position more accurately.③No system damage caused by the insufficiency of overloading competence or mechanical vibration.

    Directly bearing the effect and impact of elevator load, unstable and damageable.

    Installing and adjusting

    Just adjust the system up and down so that the indicator will turn from dark to bright. At the turning point, fasten this device well.

    Field adjustment is complicated.

    Output signal

    A pair of relay dynamic Close and Open contacts respectively.

    Single function

    Economic Analysis

    ⒈High ratio of property to price, easy use, high reliability.

    Average

  • Others:
  • Accessory: Inductive magnet [20×20×4mm3] 1 piece Fastening Nut: 2 sets

    If there is any abnormality during adjustment or operation, contact our company directly.

  • Attention: The inductive magnet is specially made of rare earth magnet with strong magnetism for this product. Take special care in the course of installation. Don’t let it close to the high temperature above 100℃ to avoid demagnetization and our company will not be responsible for the personal hurt and equipment damage arising from this.
  • Why Buy from us?

    Manufacture--Factory price,1%-2% lower than trading company offers. More discounts depend on order quantities.

    Quality--Professional technology, advanced production equipment and modern management mode, Strict QC before shipping out.

    Innovation—Independent design department, get latest product’s information. We can make your ideas into real products.

    Experience--more than 10 years production experience on elevator load weighting device,elevator load cell.

    Timely Delivery-1000,000 pcs of monthly output

    Service-- Hold the spirit of customer first, service foremost. One to one service to meet your requirement.

​My factory:

Packing:

Certificate: